Reference Number 26/00145/IN
|
Application Type Initial Notice
|
|
Status Initial Notice Accepted
|
Parish Bicester
|
|
Building Surveyor Julie Shea
|
Email julie.shea@cherwell-dc.gov.uk
|
Phone 01295 221876
|
|
Site Address Calvin Klein
137 Pingle Drive
Bicester
OX26 6EU
|
||
|
Description of Works
Unit 143 - Works to Balcony: removal of the existing casing and waterproofing to the portico (balcony), install additional joists to increase the loading capacity to the terrace and install new casing and waterproofing; remove the existing balustrades and replace with new to match the style and finish of the existing ones. Render: Removal of the existing render system (render and render carrier board); Infill of 8 windows on the Western Terrace façade to match the existing external wall construction. If the timber battens do not meet the render system requirements, they are to be removed and replaced. If the timber battens are removed and the breather membrane is damage, review if it can be remediated with patch repairs. If damage to the breather membrane is too extensive, remove it and install a new breather membrane. Installation of a new render system; Replace the rainwater drainage system with new elements to match the existing.
Unit 137-138b - Render: Removal of the existing render system to the rear service yard facing elevations (render and render carrier board). If the timber battens do not meet the render system requirements, they are to be removed and replaced. If damage to the breather membrane is too extensive, remove it and install a new breather membrane. Installation of a new render system. Replace the rainwater drainage system on the rear service yard facing elevations with new elements to match the existing.
|
||
|
Received Date 11/02/2026
|
Valid Date 13/02/2026
|
|
|
5 Week Date
20/03/2026
|
8 Week Date
10/04/2026
|
|
|
Decision |
Decision Date |
|
|
Commencement Date
20/03/2026
|
Completion Date |
|
|
Applicant
Mr JP O'Connor
|
|
|
Applicant's Address
Management Suite
Bicester Village
50 Pingle Drive
Bicester
OX26 6WD
|
|
|
Agent
SOCOTEC Building Control Limited
|
|
|
Agent's Address
SOCOTEC House
Bretby Business Park
Ashby Road
Burton Upon Trent
DE15 0YZ
|
|
|
Approved Inspector's Insurer |
Competent Persons Scheme Name
N/A
|
| Plot Address | Plot Status | Commencement Date | Completion Date |
|---|
Planning Applications | ||||||
| Application number | Valid Date | Application Type | Location | Proposal | Decision | Decision Issued Date |
|---|---|---|---|---|---|---|
| 17/00515/DISC | 19/10/2017 | Discharge Of Conditions | Former Tesco Pingle Drive Bicester OX26 6WA | Discharge condition 16 (remediation verification report)of 16/01562/F | Permitted | 05/12/2017 |
| 17/00262/DISC | 24/05/2017 | Discharge Of Conditions | Former Tesco Pingle Drive Bicester OX26 6WA | Partial Discharge of Condition 11 (hard landscaping) of 16/01562/F | Permitted | 21/07/2017 |
| 17/00409/DISC | 15/08/2017 | Discharge Of Conditions | Tesco Pingle Drive Bicester OX26 6WA | Partial discharge of condition 11 (soft landscaping) of 16/01562/F | Permitted | 18/10/2017 |
| 17/00216/DISC | 03/05/2017 | Discharge Of Conditions | Former Tesco Pingle Drive Bicester OX26 6WA | Part Discharge of Condition 11 (soft landscaping) of 16/01562/F | Permitted | 30/06/2017 |
| 17/00079/NMA | 08/06/2017 | Non Material Amendments | Former Tesco Pingle Drive Bicester OX26 6WA | Amendment to wording of Condition 8 (Proposed Non Material Amendment to 16/01562/F) | Permitted | 08/08/2017 |
| 17/00250/DISC | 18/05/2017 | Discharge Of Conditions | Former Tesco Pingle Drive Bicester OX26 6WA | Discharge of Condition 25 (public art) of 16/01562/F | Permitted | 09/06/2017 |
| 17/00253/DISC | 22/05/2017 | Discharge Of Conditions | Former Tesco Pingle Drive Bicester OX26 6WA | Partial Discharge of Condition 11 (soft landscaping) of 16/01562/F | Permitted | 21/07/2017 |
| 17/00073/NMA | 25/05/2017 | Non Material Amendments | Former Tesco Pingle Drive Bicester OX26 6WA | Non Material Amendment to 16/01562/F - Amendment to wording of condition 18 | Permitted | 06/07/2017 |
| 17/00260/DISC | 24/05/2017 | Discharge Of Conditions | Former Tesco Pingle Drive Bicester OX26 6WA | Discharge of Condition 6 (Vision Splays) of 16/01562/F | Permitted | 18/07/2017 |
| 18/01634/F | 13/09/2018 | Full Development | Former Tesco Pingle Drive Bicester OX26 6WA | Variation of Conditions 19 (factory outlet centre + 3500sq m class A3) and 22 (restriction of retailers for particular goods) of 17/00958/F and addition of a condition to 17/00958/F | Permitted | 29/03/2019 |
| 24/00451/DISC | 19/02/2024 | Discharge Of Conditions | Unit 137 and 138B Pingle Drive Bicester OX26 6WA | Discharge of Condition 4 (retail unit floor space) of 21/00271/F | Permitted | 15/04/2024 |
Building Control Applications | ||||||
| Application number | Received Date | Validated Date | Application Type | Location | Proposal | |
|---|---|---|---|---|---|---|
| 17/00586/INC | 01/06/2017 | 01/06/2017 | Initial Notice Commercial | 137 Pingle Drive Bicester OX26 6EU | Fit out of retail store to include new mezzanine floor | |
| 24/00370/IN | 15/04/2024 | Initial Notice | 137 Pingle Drive C/o 50 Pingle Drive Bicester OX26 6EU | Installation of a mezzanine floor incorporating storage and staff office, kitchenette and WC, full refit at ground floor level new fitting rooms, cash desk and associated MEP services. | ||
| 26/00145/IN | 13/02/2026 | Initial Notice | Calvin Klein 137 Pingle Drive Bicester OX26 6EU | Unit 143 - Works to Balcony: removal of the existing casing and waterproofing to the portico (balcony), install additional joists to increase the loading capacity to the terrace and install new casing and waterproofing; remove the existing balustrades and replace with new to match the style and finish of the existing ones. Render: Removal of the existing render system (render and render carrier board); Infill of 8 windows on the Western Terrace façade to match the existing external wall construction. If the timber battens do not meet the render system requirements, they are to be removed and replaced. If the timber battens are removed and the breather membrane is damage, review if it can be remediated with patch repairs. If damage to the breather membrane is too extensive, remove it and install a new breather membrane. Installation of a new render system; Replace the rainwater drainage system with new elements to match the existing. Unit 137-138b - Render: Removal of the existing render system to the rear service yard facing elevations (render and render carrier board). If the timber battens do not meet the render system requirements, they are to be removed and replaced. If damage to the breather membrane is too extensive, remove it and install a new breather membrane. Installation of a new render system. Replace the rainwater drainage system on the rear service yard facing elevations with new elements to match the existing. | ||